What was found
FLOORBEAM 32.4 IS CORRODED WHERE SEAT TRACK 5 CONTACTS IT AND ON THE UPPER SURFACE BY BL0. REMOVED CORROSION IAW SRM 51-21-00-00-02. PERFORMED THICKNESS GRID OF BLENDED AREA, MIN REMAINING THICKNESS .069" REF NDTM 51-00-04-910-801. INSPECTED BLENDED AREA FOR CRACKS USING HFEC, NO CRACKS NOTED REF NDTM 51-00-06-910-801. FOUND TO BE IN LIMITS IAW RD 8/4-53-4833. ALODINED, PRIMED IAW SRM 51-21-10-02-01 AND 51-25-10-02-01. APPLIED CPC IAW RD 8/4-53-4833. COMPLIED WITH TASK CARD RD 8/4-53-4833.