What was found
FLOORBEAM 32.4, ABOVE STR 27P IS CORRODED ON THE UPPER AND LOWER SURFACES INCLUDING THE FORWARD AND AFT SPLICES. REMOVED CORROSION IAW SRM 51-21-00-00-02. FOUND AFT SPLICE TO BE OUT OF LIMITS IAW SRM 53-20-00-00-01. REMOVED AFT SPLICE IAW SRM 51-42-05-02-01. VERIFIED AFFECTED AREA TO BE CRACK FREE REF NDTM 51-00-06-910-801 PT 1. MIN REMAINING THICKNESS .064" REF NTM 51-00-04-910-801 PT 1. MATCH DRILLED NEW SPLICE IAW SRM 51-40-07-02-0`1. ALODINED, PRIMED AND INSTALLED SPLICE IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-42-05-02-01. FOUND BLENDS TO BE IN LIMITS IAW RD 8/4-53-4880. APPLIED TOP COAT IAW SRM 51-25-15-02-01. APPLIED CPC IAW RD 8/4-53-4880. COMPLIED WITH TASK CARD RD 8/4-53-4880.