What was found
STRINGER 31P HAS CORRODED RIVETS STA 94.8-116. CLEANED AREA AND REMOVED CORRODED RIVETS IAW SRM 51-26-00-02-01 AND 51-42-05-02-01. REMOVED CORROSION FROM STRINGER IAW SRM 53-20-03-00-01. MIN REMAINING THICKNESS NOTED .071" REF NTM 51-00-04-910-801 PT 1. HFEC INSPECTED BLEND, NO CRACKS NOTED REF NDTM 51-00-06-910-801 PT 1. PERFORMED UT THICKNESS OF SKIN IAW SRM 53-00-00-02-17. FOUND TO BE IN LIMITS IAW SRM (TR53-014) 53-00-00-02-17. ALODINED, PRIMED AND INSTALLED RIVETS IAW SRM 51-42-05-02-01. RESTORED SURFACE PROTECTION IAW SRM TR 53-014.