What was found
SERVICE DOOR EDGE BEAM CORRODED. REMOVED SERVICE DOOR EDGE BEAM REF SRM 51-42-05-02-01. FOUND TO BE OUT OF LIMITS REF SRM 53-40-21-00-01. LOCATED AND DRILLED FASTENER HOLES INTO NEW SERVICE DOOR EDGE BEAM REF SRM 51-40-07-02-01. INSTALLED SERVICE DOOR EDGE BEAM REF SRM 51-42-05-02-01 AND 51-42-45-02-01. APPLIED PROTECTIVE COATINGS IAW SRM 51-25-10-02-01, 51-25-15-02-01 AND 51-21-00-00-01.