What was found
WING DRY BAY PANEL LANDING 521BT HAS AREAS OF CORROSION. REMOVED CORROSION REF RD 8/4-57-441 MIN REMAINING THICKNESS NOTED .156" REF NTM 51-00-04-910-801 PT 1. HFEC INSPECTED BLENDS, NO CRACKS NOTED REF NDTM 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND TO BE OUT OF LIMITS IAW RD 8/4-57-441. FOUND BLENDS TO BE WITHIN LIMITS IAW RD 8/4-57-1927. ALODINED BLENDED AREA IAW SRM 51-21-10-02-01. APPLIED FASTWELD AS REQUIRED IAW RD 8/4-57-1927. APPLIED SURFACE PROTECTION ON PANEL LANDING IAW RD 8/4-57-1927. COMPLIED WITH TASK CARD RD 8/4-57-1927/3.