What was found
CORROSION ON FRAME, FLANGE 258.5 STR 30P-29P THAT WAS NOT ABLE TO BE SEEN DURING UNDERFLOOR INSPECTION. REMOVED RIVET FOR ACCESS AND REMOVED CORROSION FROM FLANGE IAW RD 8/4-53-2344. CERTIFIED AFFECTED AREA TO BE CRACK FREE USING HFEC REF NDTM 51-00-06-910-801 PT 1. MIN REMAINING THICKNESS .036" REF NTM 51-00-04-910-801 PT 1. BLENDED AREA IN LIMITS IAW RD 8/4-53-2344. ALODINED AND PRIMED IAW RD 8/4-53-2344. INSTALLED FLANGE RIVETS IAW RD 8/4-53-2344. APPLIED SURFACE PROTECTION IAW RD 8/4-53-2344.