What was found
RT FUSELAGE EXTERIOR SKIN CORRODED AT AFT SERVICE DOOR CUTOUT LOWER EDGE. REMOVED CORROSION IAW SRM 51-21-00-00-02. REMOVED TWO NUTPLATES IAW SRM 51-40-07-02-01. MIN REMAINING THICKNESS NOTED .206" REF NTM 51-00-04-910-801 PT 1. HFEC INSPECTED BLENDS, NO CRACKS NOTED REF NDTM 51-00-06-910-801 PT 1. FOUND WITHIN LIMITS IAW RD 8/4-53-4896. ALODINED, PRIMED REF RD 8/4-53-4896. APPLIED TOP COAT IAW SRM 51-25-05-02-01. APPLIED CPC IAW RD 8/4-53-4896. COMPLIED WITH TC RD 8/4-53-4896. INSTALLED NEW NUTPLATES IAW SRM 51-42-05-02-01.