As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LT NR 5 FLAP TRACK INBD UPPER FLANGE HAS A WORN AREA. POLISHED WORN AREA TO REMOVE LOOSE MATERIAL AND BROKE SHARP EDGES REF SRM 57-50-50-02-01. CONFIRMED AFFECTED AREA CRACK FREE REF HORIZ NTM 8.2.1.1. MEASURED TRACK MIN REMAINING THICKNESS IS .259". MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD 8/4-57-1913.