As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLAP POWER CAUTION, FLAP HANDLE WAS NOT BEING MOVED WHEN CAUTION ILLUMINATED. FLAPS AT 0'. ATTEMPTED RESET PER EMERGENCY CHECKLIST, UNSUCCESSFULLY. LANDED WITHOUT INCIDENT. R & R THE FLAP CONTROL UNIT, THE FLAP POWER UNIT, AND THE LT FLAP POSITION TRANSDUCER. FUNCTIONAL TEST OF FLAP DRIVE SYS PERFORMED IAW AMM TASK 27-52-00-720-801. FUNCTIONARY CHECKED GOOD. FUNCTION TEST OF FLAP CONTROL SYS PERFORMED IAW AMM TASK 27-51-00-720-801. FUNCTIONARY CHECKED GOOD. RETURNED TO SERVICE.