What was found
FRAME 94.8 FLANGES ARE CORRODED STRINGER 33-30S. REMOVED RIVETS AND CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. VERIFIED BLEND AREAS CRACK FREE IAW NTM 51-00-06-910-801 PT 1 AND NTM 51-00-04-910-801 PT 1. FLANGES FOUND TO BE IN LIMITS IAW RD 8/4-53-2344. ALODINED AND PRIMED IAW RD 8/4-53-2344. INSTALLED RIVETS IAW SRM 51-42-05-02-01. PRIMED AND PAINTED INTERIOR IAW RD 8/4-53-2344. PRIMED AND PAINTED EXTERIOR IAW SRM 51-25-10-02-01 AND 51-25-15-02-01.