What was found
FRAME BS 258.5, FLANGE IS CORRODED STRINGER 32S-31S. REMOVED RIVETS AND CORROSION IAW RD 8/4-53-2344. MATERIAL FOUND TOBE OUT OF LIMITS IAW RD 8/4-53-2344. REMOVED STACHION FOM IAW SRM 51-42-05-02-01. CUT OUT CORRODED FRAME FLANGE IAW SRM 53-10-15-02-01. CONFIRMED WEB CUT OUT LINE CRACK FREE REF NTM 51-00-06-910-801 PT 1. FABRICATED REPAIR ANGLE AND LOCATED AND DRILLED TO ACFT IAW SRM 51-42-05-02-01. INSTALLED REPAIR ANGLE, STANCHION AND PACKER IAW SRM 51-42-05-02-01. APPLIED SURFACE PROTECTION IAW SRM 51-25-10-02-01, 51-25-05-02-01 AND 51-25-15-02-01.