What was found
FRAME BS 341, FLANGE IS CORRODED STRINGER 32P-31P. REMOVED RIVETS FOM IAW SRM 51-42-05-02-01. BLENDED CORROSION IAW RD 8/4-53-2344. MIN NOTED THICKNESS .053" REF NTM 51-00-4-910-801 PT 1, VERIFIED AFFECTED AREA TO BE CRACK FREE USING HFEC REF NTM 51-00-06-910-801 PT 1. NO MATERIAL LOSS NOTED NOMINAL IS .050 IAW DWG 85361315, FOUND TO BE IN LIMITS IAW RD 8/4-53-2344. ALODINED, PRIMED, INSTALLED RIVETS AND PAINTED IAW RD 8/4-53-2344 AND SRM 51-25-05-02-01.