What was found
FRAME 1, FLANGE IS CORRODED STRINGER 31P-32P. REMOVED RIVETS TO ACCESS CORROSION IAW SRM 51-42-05-02-01. BLENDED CORROSION IAW RD 8/4-53-2344. INSPECTED BLEND WITH HFEC, NO CRACK NOTED REF NDTM PT 6 TASK 51-00-01-250-801. MIN REMAINING THICKNESS .046" REF NDTM PART 1 TASK 51-00-04-910-801. FOUND FLANGES TO BE WITHIN LIMITS IAW RD 8/4-53-2344. REPLACED 3 RIVETS IAW SRM 51-42-05-02-01. ALODINED AND PRIMED FLANGE IAW SRM 51-21-10-02-01 AND 51-25-10-02-01. APPLIED SURFACE PROTECTION IAW SRM 51-25-10-02-01, 51-25-15-02-01 AND AMM 51-25-01-390-801. PAINTED EXT IAW SRM 51-25-15-02-01.