What was found
CORROSION ON FRAME -94.2 FWD SIDE ON VERTICAL WEB AT STRINGER 29P. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS .042", CONFIRMED AFFECTED AREA CRACK FREE, REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. DAMAGE IS WITHIN LIMITS IAW RD 8/4-53-4995. ALODINED, PRIMED IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-25-15-02-01. APPLIED SURFACE PROTECTION IAW AMM 51-25-01-390-801.