What was found
FRAME BS 176, FLANGES ARE CORRODED, STRINGER 29-32P. REMOVED FASTENERS, REPAIR ANGLE AND CORROSION IAW RD 8/4-53-2344. MIN REMAINING THICKNESS .029", CONFIRMED AFFECTED AREAS CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. FABRICATED AND DRILLED REPAIR ANGLE AND PACKER TO ACFT IAW RD 8/4-53-4968. ALODINED, PRIMED AND INSTALLED RIVETS IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-42-05-02-01. INSTALLED REPAIR ANGLE IAW RD 8/4-53-4968. PAINTED IAW SRM 51-25-15-02-01. COMPLIED WITH TASK CARD RD 8/4-53-4968.