What was found
FLANGE ON THE BOTTOM OF FLOORBEAM 1 HAS CORROSION ON THE FORWARD SIDE IN THE LAV AREA. REMOVED CORROSION IAW SRM 51-21-00-00-02. VERIFIED BLENDS CRACK FREE NTM 51-00-06-910-801 PT 1 AND 51-00-04-910-801 PT 1. BLENDS FOUND IN LIMITS IAW RD 8/4-55-4994. ALODINED, PRIMED, PAINTED AND APPLIED CPC IAW SRM 51-25-10-02-01, 51-21-10-02-01, 51-25-15-02-01 AND AMM 51-25-01-390-801. COMPLIED WITH TC RD 8/4-55-4994.