What was found
FRAME BS 71.2, FLANGES ARE CORRODED STRINGER 30S-32S. REMOVED RIVETS AND CORROSION IAW RD 8/4-53-2344. MIN NOTED THICKNESS .039 REF NTM 51-00-04-910-801 PT 1, CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND IN LIMITS IAW RD 8/4-53-2344. INSTALLED RIVETS, ALODINED, PRIMED FLANGES IAW RD 8/4-53-2344. APPLIED ALUMINIZED PAINT AND CPC IAW SRM 51-25-15-02-01 AND AMM 51-25-01390-801. ALODINED, PRIMED AND PAINTED EXTERIOR REPAIR AREA IAW RD 8/4-53-2344 AND SRM 51-25-05-02-01.