What was found
FRAME 136, FLANGES ARE CORRODED STRINGER 30P-32P. REMOVED RIVETS AND CORROSION IAW SRM 51-42-05-02-01 AND RD 8/4-53-2344. MIN NOTED THICKNESS .043 REF NTM 51-00-04-910-801 PT 1, CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1. FLANGES FOUND IN LIMITS IAW RD 8/4-53-2344. INSTALLED RIVETS, ALODINED, PRIMED FLANGES IAW RD 8/4-53-2344. APPLIED ALUMINIZED PAINT AND CPC IAW SRM 51-25-15-02-01 AND AMM 51-25-01390-801. ALODINED, PRIMED AND PAINTED EXTERIOR REPAIR AREA IAW RD 8/4-53-2344 AMD SRM 51-25-05-02-01.