What was found
AFT CARGO DOOR FLOOR WEB JUST FWD OF LT STEP UP HAS SURFACE CORROSION. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS NOTED .047", CONFIRMED AFFECTED AREA OF WE CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. WEB FOUND IN LIMITS IAW SRM 53-40-43-02-01. NOMINAL THICKNESS .050, MATERIAL LOSS IS .003 WITHIN LIMITS IAW SRM 53-40-43-02-01. APPLIED ALODINE IAW SRM 51-21-10-02-01, PRIMED IAW SRM 51-25-10-02-01, APPLIED ALUMINIZED PAINT IAW SRM 51-25-15-02-01.