What was found
FRAME BS 19.4, FLANGE IS CORRODED STRINGER 33-32S. REMOVED RIVETS AND CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. HFEC INSPECTED BLEND, NO CRACKS NOTED REF NDTM PART 6 TASK 51-00-01-250-801. MIN REMAINING THICKNESS .037" REF NDTM PART 1 TASK 51-00-04 910-801. FOUND FLANGE TO BE IN LIMITS IAW RD 8/4-53-2344. ALODINED, PRIMED, INSTALLED RIVETS, APPLIED TOP COAT AND CPC IAW SRM 51-21-10-02-01, 51-25-10-02-01, 51-42-05-02-01, 51-25-15-02-01 AND AMM 51-25-01-390-801.