What was found
FRAME 236 FLANGES ARE CORRODED, STRINGER 31P-32P. REMOVED RIVET FOM IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02 AND RD 8/4-53-2344. MIN REMAINING THICKNESS .046" REF NTM 51-00-04-910-801 PT 1. VERIFIED BLENDS CRACK FREE IAW NTM 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND IN LIMITS IAW RD 8/4-53-2344. ALODINED AND PRIMED IAW RD 8/4-53-2344. INSTALLED FASTENERS AND APPLIED ALUMINZIED TOP COAT REF RD 8/4-53-2344 AND SRM 51-25-05-02-01.