What was found
FRAME -18.25, FLANGE IS CORRODED STRINGER 31S-30S. REMOVED NECESSARY RIVETS AND CORROSION IAW RD 8/4-53-2344. MIN REMAINING THICKNESS .045" REF NTM 51-00-04-910-801 PT 1. VERIFIED BLENDS CRACK FREE IAW NTM 51-00-06-910-801 PT 1. FLANGE FOUND IN LIMITS IAW RD 8/4-53-2344. ALODINED AND PRIMED IAW RD 8/4-53-2344. INSTALLED FASTENERS AND APPLIED ALUMINZIED TOP COAT REF RD 8/4-53-2344 AND SRM 51-21-10-02-01, 51-25-10-02-01, 51-25-05-02-01.