What was found
FRAME 281, FLANGE IS CORRODED, STRINGER 31P-32P. REMOVED RIVET FOM IAW SRM 51-42-05-02-01. BLENDED CORROSION IAW RD 8/4-53-2344. MIN REMAINING THICKNESS .044" REF NTM 51-00-04-910-801 PT 1. VERIFIED BLENDS CRACK FREE IAW NTM 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND OUT OF LIMITS IAW RD 8/4-53-2344. REMOVED STANCHION AND CROSS BRACE FOM IAW SRM 51-42-05-02-01 AND 51-41-00-00-01. TRIMMED OFF DAMAGE FLANGE, FABRICATED REPAIR ANGLE IAW RD 8/4-53-017. CONFIRMED WEB CUT LINE CRACK FREE REF NTM 51-00-06-910-801 PT 1. INSTALLED REPAIR IAW SRM 51-41-05-02-01 AND RD 8/4-53-017.