What was found
FRAME 644.5, FLANGES ARE CORRODED STRINGER 31P-33. REMOVED RIVET FOM IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW RD 8/4-53-2344. MIN THICKNESS .056", CONFIRMED BLENDED AREAS CRACK FREE REF NTM 51-00-06-910-801 PT 1 AND NTM 51-00-04-910-801 PT 1. FLANGES FOUND TO BE IN LIMITS IAW RD 8/4-53-2344. ALODINED, PRIMED, INSTALLED RIVET AND TOP COATED IAW RD 8/4-53-2344 AND SRM 51-42-05-02-01. APPLIED TOP COAT IAW SRM 51-25-15-02-01. APPLIED CPC IAW AMM 51-25-01-390-801.