What was found
FRAME 196, FLANGE DOUBLER IS CORRODED OTBD OF STRINGER 31P. REMOVED CORRODED DOUBLER AND 3 RIVETS FROM FRAME IAW SRM 51-42-05-02-01. FOUND TO BE OUT OF LIMITS IAW RD 8/4-53-2344 WITH 100 PERCENT MATERIAL LOSS. REMOVED FRAME FLANGE IAW RD 8/4-53-017. CONFIRMED FRAME WEB CUT LINE CRACK FREE REF NTM 51-00-06-910-801, PT 1. FABRICATED AND MATCH DRILLED REPAIR ANGLE IAW RD 8/4-53-4996. TREATED, PRIMED AND PAINTED IAW RD 8/4-53-4996. INSTALLED FRAME FLANGE REPAIR ANGLE IAW RD 8/4-53-4996. COMPLIED WITH RD 8/4-53-4996.