What was found
FRAME AT STATION 32.400 HAS CORRODED BOLT HOLES ABOVE STRINGER 25P. CLEANED IAW SRM 51-26-00-02-01, NO CORROSION NOTED IN INBD BOLT HOLE. INBD HOLE REMAINS NOMINAL SIZE, OTBD BOLT HOLE REAMED TO .297 IAW SRM 51-40-07-02-01 TO REMOVE CORROSION. VERIFIED BOLT HOLE TO BE CRACK FREE USING HFEC REF NTM 51-00-05-250-801. DRILLED OTBD HOLE UP TO 0.313" IAW RD 8/4-53-4964. VERIFIED BOLT HOLE TO BE CRACK FREE USING HFEC REF NTM 51-00-05-250-801. VERIFIED BUSHING DIMENSIONS TO BE IAW RD 8/4-53-4964. INSTALLED NEW BUSHING AND NEW BOLT IAW RD 8/4-53-4964. COMPLIED WITH TASK CARD RD 8/4-53-4964.