What was found
FRAME 136 FLANGE DOUBLER IS CORRODED OTBD OF STRINGER 31P. REMOVED DOUBLER IAW SRM 51-42-05-02-01. INSPECTED WITH HFEC, NO CRACKS NOTED REF NDTM PT 6 TASK 51-00-01-250-801. MIN REMAINING THICKNESS .037" REF NDTM PT 1 TASK 51-00-04-910-801. REMOVED FLANGE IAW RD 8/4-53-017. CONFIRMED FRAME WEB AT CUT LINE CRACK FREE REF NTM 51-00-06-910-801 PT 1. REMOVED X BRACE IAW SRM 51-41-00-00-01. TRIMMED FRAME IAW RD 8/4-53-4999. FABRICATED, LOCATED DRILLED REPAIR ANGLE AND REPAIR SHIM IAW RD 8/4-53-4999. TREATED AND PAINTED IAW RD 8/4-53-4999. INSTALLED FRAME FLANGE REPAIR ANGLE IAW RD 8/4-53-4999. COMPLIED WITH TASK CARD RD 8/4-53-4999. RE-INSTALLED X BRACE IAW SRM 51-41-05-00-01.