As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ATTACH ANGLE CONNECTING INTERCOSTAL 25P TO FLOOR SUPPORT WEB 6.7 CORRODED. REMOVED CLIP IAW SRM 51-42-05-02-01, 51-40-15-02-01. MATCH DRILLED NEW CLIP TO AC IAW SRM 51-40-07-02-01. INSTALLED NEW CLIP IAW SRM 51-42-05-02-01, 51-40-15-02-01. TREATED CLIP IAW SRM 51-25-15-02-01.