What was found
FRAME 94.8, FOWARD SIDE IS CORRODED ON THE OTBD SIDE OF STRINGER 31P. REMOVED CORROSION IAW SRM 51-42-05-02-01. MIN REMAINING THICKNESS .031", CONFIRMED AFFECTED AREA CRACK FREE, REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. DAMAGE IS WITHIN LIMITS IAW RD 8/4-53-4988. ALODINED, PRIMED IAW SRM 51-21-10-02-01, 51-25-10-02-01. ALUMINIZED, PRIMED AND PAINTED IAW RD 8/4-53-4988. COMPLIED WITH TASK CARD RD 8/4-53-4988.