What was found
FRAME 32.4, FLANGES ARE CORRODED STRINGER 33-30S. REMOVED RIVETS AND CORROSION IAW SRM 51-42-05-02-01 AND RD 8/4-53-2344 MIN NOTED THICKNESS .035" REF NTM 51-00-04-910-801 PT 1. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND OUT OF LIMITS IAW RD 8/4-53-2344. REMOVED STANCHION IAW SRM 51-42-05-02-01. TRIMMED FRAME FLANGE IAW RD 8/4-53-017 VERIFIED TRIMMED FRAME EDGE CRACK FREE IAW NTM 51-00-06-910-801 PT 1. FABRICATED DRILLED LOCATED REPAIR ANGLE IAW RD 8/4-53-017. ALODINED, PRIMED REPAIR ANGLE IAW RD 8/4-53-017. INSTALLED ANGLE AND STANCHION IAW RD 8/4-53-017 AND SRM 51-42-05-02-01. APPLIED ALUMINIZED PAINT AND CPC IAW RD 8/4-53-017.