What was found
FRAME 19.4, FLANGES ARE CORRODED, STRINGER 32P-29P. REMOVED RIVETS FOM AND REMOVED CORROSION IAW SRM 51-42-05-02-01 AND RD 8/4-53-2344. VERIFIED BLENDS CRACK FREE IAW NTM 51-00-06-910-801 PT 1 AND NTM 51-00-04-910-801 PT 1. MATERIAL LOSS FOUND IN LIMITS IAW RD 8/4-53-2344. INSTALLED RIVETS IAW SRM 51-42-05-02-01. RESTORED EXTERIOR SURFACE PROTECTION AND ALODINED, PRIMED, TOP COATED AND CPC INTERIOR SURFACES IAW RD 8/4-53-2344.