What was found
FRAME 236, CORRODED ON MATING SURFACE OF STANCHION AT STRINGER 31P. REMOVED CORROSION IAW SRM 51-21-00-00-02. PERFORMED THICKNESS GRID OF BLENDED AREA MIN REMAINING THICKNESS .038" REF NDTM PT 1 TASK 51-00-04-910-801. INSPECTED BLENDED AREA FOR CRACKS WITH HFEC, NO CRACKS DETECTED REF NDTM PT 6 TASK 51-00-01-250-801. ALODINED AND PRIMED IAW SRM 51-21-10-02-01 AND 51-25-10-02-01. APPLIED TOP COAT TO AREAS IAW SRM 51-25-15-02-01. FOUND BLENDS TO BE WITHIN LIMITS IAW RD 8/4-53-5005. COMPLIED WITH TASK CARD RD 8/4-53-5005.