What was found
FLOORBEAM 32.4 HAS CORROSION AT THE LT SPLICE INCLUDING SPLICE PIECES. REMOVED LT SPLICE PIECES FLOORBEAM 32.4 IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02. SPLICES FOUND TO BE OUT OF LIMITS IAW SRM 53-20-43-00-01. REMOVED FLOORBOARD SUPPORT BRACKET IAW SRM 51-42-05-02-01 FOUND TO BE OUT OF LIMITS IAW SRM 53-20-43-00-01. MIN REMAINING THICKNESS NOTED .072" CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. APPLIED ALODINE, PRIMER TO FLOORBEAM IAW SRM 51-21-10-02-01 AND 51-25-10-02-01. MATCH DRILLED NEW SPLICES AND FLOOR SUPPORT BRACKET IAW SRM 51-40-07-02-01. INSTALLED SPLICES AND FLOOR SUPPORT BRACKET IAW SRM 51-42-05-02-01. APPLIED TOP COAT AND CPC IAW SRM 51-25-15-02-01 AND AMM 51-25-01-390-801. MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD 8/4-53-4979. COMPLIED WITH TC RD 8/4-53-4979.