What was found
FRAME 49.5 FLANGE IS CORRODED STRINGER 33-32S. REMOVED RIVETS AND CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. INSPECTED WITH HFEC, NO CRACKS NOTED REF NDTM PT 6 TASK 51-00-01-250-801. MIN REMAINING THICKNESS .045" REF NDTM PT 4 TASK 51-00-02-250-801. FLANGE FRAME 49.5 FOUND TO BE IN LIMITS IAW RD 8/4-53-4975. APPLIED PRIMER AND TOP COAT IAW SRM 51-25-15-02-01 AND 51-25-10-02-01. INSTALLED RIVETS IAW RD 8/4-53-4975. COMPLIED WITH TC RD 8/4-53-4975.