What was found
MULTIPLE NICKS AND AN UNIDENTIFIED BLEND FWD OF BS 1.000 TO 32.400 STRINGERS 25S-27S. REMOVED PAINT FROM UNIDENTIFIED BLEND AREA AND MULTIPLE NICK AREA IAW SRM 51-26-10-02-01. SMOOTHED AREA OF MULTIPLE NICKS AFT OF LAV SERVICE DOOR IAW SRM 53-00-00-02-01. MIN THICKNESS IN AFFECTED AREA NOTED .082" REF NTM 51-00-02-250-801, PT 4. CONFIRMED AFFECTED AREA OF SKIN CRACK FREE REF NTM 51-00-06-910-801, PT 1. ALODINED, PRIMED AND PAINTED IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND AMM 51-25-01-390-801. APPLIED YELLOW DOT IAW GPM 10.11.3. NICKS FOUND TO BE IN LIMITS IAW RD 8/4-53-666. APPLIED TOP COAT IAW SRM 51-25-15-02-01 COMPLIED WITH TC RD 8/4-53-5020.