What was found
FRAME 49.5, REPAIR FLANGE IS CORRODED, STRINGER 29P-30P. REMOVED REPAIR IAW SRM 51-42-05-02-01. FRAME FOUND TO BE OUT OF LIMITS IAW SRM 53-20-15-00-01. REMOVED FRAME 49.5 AND MATCH DRILLED NEW FRAME IAW RD 8/4-53-4975. FABRICATED STRAP AND MATCH DRILLED STRAP IAW RD 8/4-53-4975. CONFIRMED FRAME CUT LINE CRACK FREE REF NTM 51-00-06-910-801 PT 1. INSTALLED NEW FRAME SECTION SPLICE AND STRAP IAW RD 8/4-53-4975. COMPLIED WITH TC RD 8/4-53-4975.