What was found
FRAME 664.5, FLANGE IS CORRODED, STRINGER 23P-24P. REMOVED FASTENERS AND REMOVED CORROSION IAW RD 8/4-53-2344. MIN REMAINING THICKNESS .050", VERIFIED BLENDS CRACK FREE IAW NTM 51-00-06-910-801 PT 1 AND NTM 51-00-04-910-801 PT 1. INSTALLED FASTENERS IAW SRM 51-40-15-02-01. MATERIAL LOSS FOUND IN LIMITS IAW RD 8/4-53-4989. APPLIED ALODINE, PRIMER AND PAINT IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-25-15-02-01. RESTORED SURFACE PROTECTION IAW RD 8/4-53-4989. COMPLIED WITH TC RD 8/4-53-4989.