What was found
STRINGER 24S IS CORRODED, STA 564.5-624.5. NO REPAIRS ALLOWED TO STRINGER IAW SRM 53-40-03-00-01. REMOVED STRINGER IAW SRM 51-40-07-02-01 AND 51-40-15-02-01. MATCH DRILLED NEW STRINGER IAW SRM 51-40-07-02-01. INSTALLED STRINGER IAW SRM 51-42-05-02-01. INSTALLED STRINGER SPLICE AND CLIPS IAW SRM 51-42-05-02-01. ALODINED, PRIMED, TOP COATED AND CPC IAW SRM 51-21-10-02-01, 51-25-10-02-01, 51-20-00-00-01 AND AMM 51-25-01-390-801.