What was found
STRINGER 31P HAS CORRODED RIVETS AND POSSIBLE CORROSION STA 49.5-71.2. REMOVED RIVETS TO FOM AND REMOVED CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. INSPECTED BLEND WITH HFEC , NO CRACKS NOTED REF NDTM PT 6 TASK 51-00-01-250-801. MIN REMAINING THICKNESS .063" REF NDTM PT 4 TASK 51-00-02-250-801. FOUND OUT OF LIMITS IAW SRM 53-00-00-02-17 TEMP REVISION 53-014, JULY 17, 2012. PERFORMED UT THICKNESS CHECK IAW NTM 51-00-04-910-801 PT 1. MIN REMAINING MATERIAL MEASURED 0.063 VERIFIED BLENDS ARE CRACK FREE WITH HFEC IAW NTM 51-00-06-910-801 PT 1. ALODINED, PRIMED IAW SRM 51-21-10-02-01 AND 51-25-10-02-01. INSTALLED RIVETS IAW SRM 51-42-05-02-01, APPLIED TOP COAT AND CPC IAW SRM 51-25-15-02-01 AND AMM 51-25-01-390-801. CORROSION REMOVAL FOUND TO BE IN LIMITS IAW RD 8/4-53-4971. COMPLIED WITH TC RD 8/4-53-4971.