As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOORBEAM 683.45 IS CRACKED AT THE SERVICE DOOR END. REMOVED FLOORBEAM 683.45 IAW SRM 51-42-05-02-01. REMOVED UPPER FLOORBOARD SUPPORT ANGLE IAW SRM 51-42-05-02-01. LOCATED AND DRILLED NEW FLOORBEAM IAW SRM 51-40-07-02-01. INSTALLED FLOORBEAM AND ASSOCIATED PARTS IAW SRM 51-42-05-02-01. INSTALLED FLOORBOARD SUPPORT IAW SRM 51-42-05-02-01. RESTORED SURFACE PROTECTION IAW SRM 51-25-10-02-01.