What was found
FRAME 836.452 HAS A SPOT OF CORROSION AT FLOOR LEVEL ABOVE STRINGER 25S. REMOVED FASTENER FROM FRAME IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02 MIN REMAINING THICKNESS NOTE .038" CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801, PT 1 AND 51-00-06-910-801, PT 1. INSTALLED FASTENER TREATED AND PAINTED REF SRM 51-42-05-02-01, 51-21-10-02-01 AND 51-25-15-02-01. FOUND BLENDS TO BE WITHIN LIMITS IAW RD 8/4-53-4990. APPLIED CPC TO AFFECTED AREA IAW TC RD 8/4-53-4990. COMPLIED WITH TC RD 8/4-53-4990.