What was found
LEFT UPPER WING LANDING FOR ACCESS PANEL 521BT HAS AREAS OF CORROSION. REMOVED CORROSION FROM LANDING IAW RD 8/4-57-441. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1 MIN REMAINING THICKNESS .168" REF NTM 51-00-04-910-801 PT 1. FOUND OUT OF LIMITS IAW RD 8/4-57-441. ALODINED AND PRIMED IAW SRM 51-21-10-02-01 AND 51-25-40-02-01. DAMAGE FOUND TO BE IN LIMITS RD 8/4-57-1972. COMPLIED WITH TC RD 8/4-57-1972.