What was found
FWD LANDING STRIP ON 262HT MATING SURFACE HAS FRETTING. BLENDED OUT DAMAGE. COMPLIED WITH TC RD 8/4-57-1980. SRM 53-75-46-02-01 MIN THICKNESS NOTED .065, CONFIRMED AFFECTED AREAS CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. TREATED, PRIMED IAW SRM 53-75-06-02-01. REPLACED RIVETS AS REQUIRED IAW SRM 51-42-05-02-01. ALODINED IAW SRM 51-21-10-02-01. FILLED BLENDS FLUSH IAW SRM 51-22-20-02-01 AND APPLIED PRIMER IAW SRM 51-25-10-02-01. APPLIED TEFLON TAPE IAW SRM 57-10-05-02-01. FOUND LANDING STRIP SURFACE CONDITION TO BE WITHIN LIMITS IAW RD 8/4-57-1980.