What was found
FWD LANDING STRIP ON 262AT MATING SURFACE HAS FRETTING. BLENDED OUT DAMAGE ON PANEL AND LANDING IAW SRM 53-75-06-02-01. MIN NOTED THICKNESS .063" CONFIRMED BLENDS CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. TREATED, PRIMED IAW SRM 53-75-06-02-01. ALODINED LANDING IAW SRM 51-21-10-02-01. REPLACED RIVETS AS REQUIRED IAW SRM 51-42-05-02-01. FILLED BLENDS FLUSH IAW SRM 51-22-20-02-01 AND APPLIED PRIMER IAW SRM 51-25-10-02-01. COMPLIED WITH TC RD 8/4-57-1980.