What was found
STRINGER 25P CORRODED AT END FITTING APPROX STA 664.5. REMOVED END FITTING IAW SRM 51-40-15-02-01, 51-42-05-02-01 TO FOM. FOUND STRINGER UNDER END FITTING TO BE CRACKED. CUT OUT STRINGER IAW RD 8/4-53-4967. CONFIRMED STRINGER CUT LINE AND REPAIR AREAS CRACK FREE REF NTM 51-00-06-910-801 PT 1 AND RD 8/4-53-4967. FABRICATED NEW STRINGER SECTION AND SPLICE IAW RD 8/4-53-4967. LOCATED SPLICE AND MATCH DRILLED TO ACFT IAW RD 8/4-53-4967. TREAT AND PRIMED ALL AFFECTED AREAS IAW RD 8/4-53-4967. INSTALLED REPAIR IAW RD 8/4-53-4967. RECEIVED NEW STRINGER TIE FITTING LOCATED AND MATCH DRILLED TO ACFT IAW SRM 51-40-07-02-01. INSTALLED FITTING AND RESTORED SURFACE PROTECTION IAW RD 8/4-53-4967. COMPLIED WITH HZ TC RD 8/4-53-4967.