What was found
CORROSION ON AFT SIDE OF FRAME X882.703 AND FWD SKIN ATTACHING ANGLE OF CANTED FRAME AT STA TR X105 BETWEEN STR 30P AND 30S. REMOVED FASTENERS COMMON TO SKIN AND FWD SKIN ATTACHING ANGLE, REMOVED CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-01. MIN REMAINING THICKNESS NOTED FRAME .039" FLANGE .062" CONFIRMED BOTH CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. APPLIED ALODINE IAW SRM 51-21-10-02-01 APPLIED PRIMER IAW SRM 51-25-10-02-01. INSTALLED FASTENERS IAW SRM 51-42-05-02-01. APPLIED PAINT AND PRIMER IAW SRM 51-25-10-02-01 AND 51-25-15-02-01. APPLIED CPC IAW AMM 51-25-01-390-801. FOUND BLENDS IN LIMITS IAW RD 8/4-55-814. COMPLIED WITH TC RD 8/4-55-814.