What was found
FRAME 32.4 HAS CORROSION ON THE FLANGES AND BOTH SIDES OF THE WEB STRINGER 29S-28P. REMOVED RIVETS AND X BRACE FOM IAW SRM 51-41-00-00-01 AND 51-42-05-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02 AND FOUND TO BE OUT OF LIMITS DUE TO 100 PERCENT MATERIAL LOSS IAW SRM 53-20-15-00-01. MIN REMAINING THICKNESS .033, CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. RT FRAME FLANGE MIN .033" OUT OF LIMITS IAW RD 8/4-53-2344. REMOVED GUSSET, UPPER AND LOWER SPLICE TO FOM FRAME REMOVAL IAW SRM 51-42-05-02-01. MATCH DRILLED NEW FRAME SECTION IAW SRM 51-40-07-02-01. INSTALLED NEW FRAME SECTION, UPPER AND LOWER SPLICE AND GUSSET IAW SRM 51-42-05-02-01. REINSTALLED X BRACE IAW AMM 20-10-01-430-801 AND RIVETS IAW SRM 51-42-05-02-01. ALODINED AND PRIMED IAW SRM 51-21-10-02-01 AND 51-25-10-02-01. APPLIED PAINT AND CPC TO FLANGES IAW SRM 51-25-15-02-01 AND AMM 51-25-01-390-801. COMPLIED WITH TC RD 8/4-53-4969.