What was found
STRINGER 28S, HAS CORROSION STA X-39 TO X-18.25. REMOVED NECESSARY RIVETS IAW SRM 51-42-05-02-01. REMOVED Z-CHANNEL IAW SRM 51-42-05-02-01 AND REMOVED CORROSION IAW SRM 51-21-00-00-02. FOUND OUT OF LIMITS IAW SRM 53-10-33-00-01, MATCH DRILLED NEW Z CHANNEL IAW SRM 51-40-07-02-01. INSTALLED Z-CHANNEL IAW SRM 51-42-05-02-01. BLENDS FOUND TO BE IN LIMITS IAW RD 8/4-53-5146. VERIFIED BLENDS CRACK FREE IAW NTM 51-00-06-910-801 PT 1. ALODINED, PRIMED AND INSTALLED RIVETS IAW RD 8/4-53-5146. APPLIED ALUMINIZED PAINT IAW RD 8/4-53-5146. APPLIED EXTERNAL TOP COAT IAW SRM 51-25-15-02-01.