As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LT WING ACCESS PANEL 522BT HAS DAMAGE AROUND FASTENER HOLE AND MISSING PAINT. BLENDED OUT DAMAGE AROUND FASTENER HOLE. NOMINAL THICKNESS 0.225", REMAINING THICKNESS IS 0.220" AND IS WITHIN LIMITS IAW RD 8/4-57-425. PREPPED MISSING PAINT AREAS IAW SRM 51-25-40-02-01. VERIFIED AFFECTED AREA TO BE CRACK FREE USING HFEC REF NDTM PT 1 TASK 51-00-06-910-801 AND RD 8/4-57-425. ACCOMPLISHED STEPS 4-7 OF RD 8/4-57-425.