What was found
FRAME 1.0, FLANGES ARE CORRODED STR 33-31S. REMOVED RIVETS AND CORROSION IAW SRM 51-42-05-02-01, 51-21-00-00-02. NOMINAL THICKNESS .050" AND NO REPAIRS ALLOWED IAW SRM 53-20-15-00-01. MIN THICKNESS NOTED .046" CONFIRMED CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. UPON FURTHER INVESTIGATION FRAME 1.0 FLANGE FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-2344. INSTALLED RIVETS IAW SRM 51-42-05-02-01. APPLIED ALODINE, PRIMED IAW RD 8/4-53-2344. APPLIED ALUMINIZED PAINT IAW SRM 51-25-15-02-01. APPLIED CPC IAW AMM 51-25-01-390-801. APPLIED ALODINE PRIMER AND PAINT TO EXTERIOR SURFACE IAW SRM 51-21-10-02-01, SRM 51-25-10-02-01 AND AMM 51-25-31-370-801.